Review of Boulos PR et. al. In the eye of the beholder–skin rejuvenation using a light-emitting diode photomodulation device

April 12, 2009

http://www.ncbi.nlm.nih.gov/pubmed/19215260

Dermatol Surg. 2009 Feb;35(2):229-39.

In the eye of the beholder–skin rejuvenation using a light-emitting diode photomodulation device

Boulos PR, Kelley JM, Falcão MF, Tremblay JF, Davis RB, Hatton MP, Rubin PA

Review copyright 2009 https://aestheticdevicereview.wordpress.com

In an unusual article, Boulos and colleagues present compelling evidence that the GentleWaves LED device simply does not work, and that patient satisfaction is simply the result of a placebo effect.

In this study, 36 patients were treated with the GentleWaves device weekly for 8 weeks, as suggested by several other researchers.  Standardized photography was performed pre-treatment, immediately post-treatment, and 1 month post-treatment.  The unblinded investigator also performed clinical assessments at the same time points.

Thirty raters were asked to select the “after” photo from a randomly ordered before/after pair, looking at one of five aspects of the treatment – redness, wrinkles, dark spots, skin roughness, and general appearance.  Unfortunately, the results were not different from chance.

The data were re-evaluated by using a consensus of three raters for each aspect.  Still, the results were no different from chance.

Next, statistical power was increased by using raters’ confidence in their own judgements to weight the data.  In other words, this analysis more highly weighted the decisions that the raters felt sure about, and underweighted the decisions where the raters felt unsure.  Nevertheless, results again were not different from chance.

Finally, the unblinded investigator’s clinical assessments showed that “there was essentially no effect, or if anything, a negative effect.”

Despite the lack of any objective evidence of improvement whatsoever, patients were quite pleased with the results.  The authors conclude that the treatment is a classic placebo, where patients feel better because they believe that the treatment will work, even though it does nothing.  At AestheticDeviceReview, we would like to see more devices subjected to this type of study.


Review of Jørgensen GF, et.al. Long-pulsed dye laser versus intense pulsed light for photodamaged skin

January 30, 2009

http://www.ncbi.nlm.nih.gov/pubmed/18563775

Lasers Surg Med. 2008 Jul;40(5):293-9.

Long-pulsed dye laser versus intense pulsed light for photodamaged skin: a randomized split-face trial with blinded response evaluation.

Jørgensen GF, Hedelund L, Haedersdal M.

Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark.

 

 

In this paper, Gitte Jørgensen reports a rarely seen type of study in the aesthetic space – a randomied comparison of two competing device technologies.  The study was co-sponsored by both device manufacturers, but neither manufacturer participated in the conduct or analysis of the study.  Most aesthetic device studies compare a device treatment to an untreated control, to show that the treatment causes some effect.  In contrast, this study compared the Candela VBeam Perfecta (long pulse 595nm dye laser) with the Ellipse Flex (Intense Pulsed Light) for the treatment of photodamaged skin, to see if the treatments caused different outcomes

The study was well-designed to demonstrate the differences with each type of treatment.  First, the patient population was homogenous (light skin females).  Reduction of patient variability reduces confounding of outcomes and enables smaller sample sizes.  Second, each study participant received a series of 3 split-face treatments with the one side randomized to each device type, which properly controls for non-study effects (e.g. additional sun exposure).  The use of the series of 3 treatments would magnify outcome differences, if there were any.  Third, the evaluation was performed on-site by a blinded, independent physician, to prevent bias and to prevent the introduction of photographic artifact.  Although blinding adequately prevents bias, agreement from multiple blinded observers would be useful to reduce individual subjectivity in the assessment of improvement.

While both devices demonstrated improved outcomes in this study, the long pulse 595nm dye laser achieved overall superior results, due to superior performance on vascular lesions.  Fourteen of 20 patients obtained better clearing of telangiectasias with the pulsed dye laser and the remainder saw no difference.  The difference in lightening was both statistically and clinically significant (i.e. the difference in lightening was visually apparent to the blinded reviewer and the patient). Both devices achieved similar improvements for irregular pigmentation and skin texture.  Neither device showed any improvement in wrinkles/rhytids.  Eighteen of 20 patients preferred the pulsed dye laser, both because of improved vascular clearance and because there was less treatment-related pain.

Despite an excellent study design, there are some limitations to the study conclusions.  The superior results of the pulse dye laser should not be considered definitive, as there was no-pre-defined study hypothesis to be proven.  The study was too small to determine whether there was a significant difference in the rates of adverse effects between the two devices.  Because both devices demonstrated improvement in outcomes, practitioners may be able to achieve pulsed-dye-laser results by simply performing additional IPL treatments.  Possibly, other IPL systems may perform better than the Ellipse product used in this study.